DESCRIPTION: Bovie IDS 310 Features

  • The Bovie IDS 310, designed in conjunction with OR clinicians, offers a safe and user-friendly generator to meet all operating room procedure performance demands.
  • Provides 13 modes of surgical energy delivery, including special modalities such as Bovie Bipolar, Auto Bipolar, and specialized Laparoscopic modes.
  • Bovie Bipolar: Pulsing coagulation for quick and powerful tissue coagulation.
  • Auto Bipolar: Simplified tissue coagulation with minimal tissue damage.
  • Specialized Laparoscopic Mode: Recalls up to 10 presets and up to 6 bipolar output preferences.
  • Adjustable Power During Activation.

SPECIFICATIONS: Bovie IDS 310 Specifications

  • Dimensions:
    • Height: 6.5 In (16.5 cm)
    • Width: 14.75 In (37.5 cm)
    • Depth: 18.1 In (46 cm)
    • Weight: < 20 lb (< 9.07 kg)
  • General:
    • Contact Monitoring Systems: BovieNEM
    • Range/Trip Point: 10 ohms or less over entire operating range (10C° to 40°C)
    • Cooling System: Passive Cooling
    • Technology: Isolated RF Output
    • Pre-set Feature: Yes
    • Monopolar HP Ports: 2
    • Dual Activation Tone Alert: Yes
    • Connector Ports/Power Switch: Black
  • Operating Parameters:
    • Ambient temperature range: 10° to 40° C
    • Relative humidity: 30% to 75%, non-condensing
    • Atmospheric pressure: 70kPa to 106kPa
    • Warm-up time: If transported or stored at temperatures outside the operating temperature range, allow one hour for the generator to reach room temperature before use.
  • Transport:
    • Ambient temperature range: -40° to +70° C
    • Relative humidity: 10% to 100%, including condensation
    • Atmospheric pressure: 50kPa to 106kPa
  • Storage:
    • Ambient temperature range: 10° to 30° C
    • Relative humidity: 30% to 75%, non-condensing
    • Atmospheric pressure: 50kPa to 106kPa
  • Bipolar:
    • Macro Bipolar:
      • Watts: 150
      • VPeak Max Voltage: 600V
      • Crest Factor (Typical): 1.5 ± 20%
      • Frequency: 490 kHz ± 4.9 kHz
    • Micro Bipolar:
      • Watts: 80
      • VPeak Max Voltage: 450V
      • Crest Factor (Typical): 1.5 ± 20%
      • Frequency: 490 kHz ± 4.9 kHz
    • Standard Bipolar:
      • Watts: 50
      • VPeak Max Voltage: 300V
      • Crest Factor (Typical): 1.5 ± 20%
      • Frequency: 490 kHz ± 4.9 kHz
    • Bovie Bipolar:
      • Watts: 225
      • VPeak Max Voltage: 250V
      • Crest Factor (Typical): 1.5 ± 20%
      • Frequency: 490 kHz ± 4.9 kHz
    • Auto Bipolar:
      • Watts: 80
      • Frequency: 490 kHz ± 4.9 kHz
    • Monopolar:
      • Cut I:
        • Watts: 300
        • VPeak Max Voltage: 1000V
        • Crest Factor (Typical): 1.7 ± 20%
        • Frequency: 490 kHz ± 4.9 kHz
      • Cut II:
        • Watts: 300
        • VPeak Max Voltage: 750V
        • Crest Factor (Typical): 1.7 ± 20%
        • Frequency: 490 kHz ± 4.9 kHz
      • Blend (1) – Blend (4):
        • Watts: 200
        • VPeak Max Voltage: (Varies)
        • Crest Factor (Typical): (Varies)
        • Frequency: 490 kHz ± 4.9 kHz
      • Pinpoint Coagulation:
        • Watts: 120
        • VPeak Max Voltage: 1800V
        • Crest Factor (Typical): 3.1 ± 20%
        • Frequency: 490 kHz ± 4.9 kHz
      • Spray Coagulation:
        • Watts: 120
        • VPeak Max Voltage: 4000V
        • Crest Factor (Typical): 6.0 ± 20%
        • Frequency: 350 to 450 kHz
      • Gentle Coagulation:
        • Watts: 120
        • VPeak Max Voltage: 450V
        • Crest Factor (Typical): 1.6 ± 20%
        • Frequency: 490 kHz ± 4.9 kHz