Zoll M Series CCT

Single Product Request Form
Category

Description

Features:

  • Defibrillator with AED features
  • Compact, portable, and lightweight design suitable for various situations
  • Offers pacing, 12-lead ECG, SpO2, EtCO2, NIBP, AED, and temperature monitoring
  • 6.5-inch color LCD screen with Rectilinear Biphasic waveforms
  • Real-time documentation and data transfer capabilities via memory or removable PCMIA cards
  • Superior defibrillation and pacing capabilities
  • Advisory functions for patient assessment
  • Easy-to-read display in any lighting condition
  • Full range of parameters for comprehensive patient monitoring
  • Quick and easy connections

Specifications:

  • Dimensions:
  • With NIBP, IBP, Temp:
    • Height: 10.2 in (25.9 cm)
    • Width: 10.3 in (26.2 cm)
    • Depth: 8.7 in (22.1 cm)
  • Without NIBP, IBP, Temp:
    • Height: 8.6 in (21.8 cm)
    • Width: 10.3 in (26.2 cm)
    • Depth: 8.7 in (22.1 cm)
  • Weight:
  • With multi-function cable and battery: 17.2 lb (7.8 kg)
  • With paddles, above items: 19.2 lb (8.71 kg)
  • AC Power: 100-120 V, 50/60 Hz; 220-240 V, 50 Hz; 220 VA
  • Display Specifications:
  • Screen type: Active Matrix Color LCD
  • Screen Size: 6.5 in (16.51 cm) Diagonal
  • Number of Pixels: 640 x 480
  • Battery Specifications (XL Battery pack):
  • Type: Rechargeable, sealed lead acid
  • Weight: 3.7 lbs (1.68 kg)
  • Voltage: 2 volts/cell; 5 cells wired in series
  • Recharge Time: 7.2 hours or less
  • Operating Time: 60 defibrillator discharges at maximum energy (200 J), or 2.5 hours minimum of continuous ECG and SpO2 monitoring, or 1.5 hours of continuous ECG, SpO2, EtCO2, IBP, and Temperature monitoring/pacing at 60 mA, 70 beats per minute.
  • Environmental Specifications:
  • Operating Temperature: 32° to 122° F (0° to 50° C)
  • Storage and Shipping Temperature: -4° to 140° F (-20° to 60° C)
  • Humidity: 5 to 95% relative humidity, non-condensing
  • Vibration: Mil-Std 810 E, Minimum Integrity Test
  • Shock: IEC 68-2-27, 50g 6mS half-sine
  • Operating Pressure: 594 to 1060 millibars
  • Defibrillator:
  • Waveform: ZOLL Rectilinear Biphasic
  • Energy Selection: Selectable at 1 to 200 joules
  • Charge Time: Less than 6 seconds
  • Synchronized Mode: Synchronizes defibrillator pulse to the patient’s R-wave
  • ECG Monitoring:
  • Bandwidth: 0.5-40 Hz (-3 dB) standard/0.05-150 Hz diagnostic
  • Heart Rate: Digital display 0-300 bpm ±5%
  • Lead Selection: Displayed on the monitor
  • CPR Monitoring:
  • Compression Depth: 0.75 to 3 inches (1.9 to 7.6 cm)
  • Compression Rate: 50 to 150 compressions per minute