SPECIFICATIONS: Bovie IDS 310 Specifications
- Dimensions:
- Height: 6.5 In (16.5 cm)
- Width: 14.75 In (37.5 cm)
- Depth: 18.1 In (46 cm)
- Weight: < 20 lb (< 9.07 kg)
- General:
- Contact Monitoring Systems: BovieNEM
- Range/Trip Point: 10 ohms or less over entire operating range (10C° to 40°C)
- Cooling System: Passive Cooling
- Technology: Isolated RF Output
- Pre-set Feature: Yes
- Monopolar HP Ports: 2
- Dual Activation Tone Alert: Yes
- Connector Ports/Power Switch: Black
- Operating Parameters:
- Ambient temperature range: 10° to 40° C
- Relative humidity: 30% to 75%, non-condensing
- Atmospheric pressure: 70kPa to 106kPa
- Warm-up time: If transported or stored at temperatures outside the operating temperature range, allow one hour for the generator to reach room temperature before use.
- Transport:
- Ambient temperature range: -40° to +70° C
- Relative humidity: 10% to 100%, including condensation
- Atmospheric pressure: 50kPa to 106kPa
- Storage:
- Ambient temperature range: 10° to 30° C
- Relative humidity: 30% to 75%, non-condensing
- Atmospheric pressure: 50kPa to 106kPa
- Bipolar:
- Macro Bipolar:
- Watts: 150
- VPeak Max Voltage: 600V
- Crest Factor (Typical): 1.5 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Micro Bipolar:
- Watts: 80
- VPeak Max Voltage: 450V
- Crest Factor (Typical): 1.5 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Standard Bipolar:
- Watts: 50
- VPeak Max Voltage: 300V
- Crest Factor (Typical): 1.5 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Bovie Bipolar:
- Watts: 225
- VPeak Max Voltage: 250V
- Crest Factor (Typical): 1.5 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Auto Bipolar:
- Watts: 80
- Frequency: 490 kHz ± 4.9 kHz
- Monopolar:
- Cut I:
- Watts: 300
- VPeak Max Voltage: 1000V
- Crest Factor (Typical): 1.7 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Cut II:
- Watts: 300
- VPeak Max Voltage: 750V
- Crest Factor (Typical): 1.7 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Blend (1) – Blend (4):
- Watts: 200
- VPeak Max Voltage: (Varies)
- Crest Factor (Typical): (Varies)
- Frequency: 490 kHz ± 4.9 kHz
- Pinpoint Coagulation:
- Watts: 120
- VPeak Max Voltage: 1800V
- Crest Factor (Typical): 3.1 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Spray Coagulation:
- Watts: 120
- VPeak Max Voltage: 4000V
- Crest Factor (Typical): 6.0 ± 20%
- Frequency: 350 to 450 kHz
- Gentle Coagulation:
- Watts: 120
- VPeak Max Voltage: 450V
- Crest Factor (Typical): 1.6 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Cut I:
- Macro Bipolar: