Criticare VitalCare 506N3

Single Product Request Form

Description

Features:

  • Non-invasive blood pressure monitor capable of monitoring blood pressure, pulse oximetry, and predictive temperature.
  • ComfortCuff NIBP technology for faster and more comfortable readings.
  • Choice between CSI’s DOX or Nellcor OxiMax pulse oximetry.
  • Adjustable audible and visual alarms for continuous monitoring.
  • Large responsive keys and easy-to-clean membrane keypad for fast spot-checks.
  • Accommodates patients of all ages, from adults to neonates.
  • Multi-patient trend memory for comprehensive monitoring.
  • Rechargeable battery with direct AC power option.
  • Optional FILAC or Alaris TurboTemp predictive temperature for quick and accurate measurements.
  • Optional integrated printer for on-demand, automatic interval, trends, or multi-patient reports.

Specifications:

  • Non-Invasive Blood Pressure:
    • Technique: Oscillometric measure upon inflation
    • Measurement Time: <40 seconds typical
    • Automatic Measurement Cycles: 1 – 60 minutes; 2 – 4 hours; STAT
    • Inflation Pressure Range: 30 to 300 mmHg (Adult), 30 to 150 mmHg (Pediatric), 20 to 150 mmHg (Neonate)
  • Pulse Oximetry:
    • Range: 1% to 99%
    • Resolution: 1%
    • Accuracy (DOX): ±2% (70% to 99% range), ±3% (50% to 69% range), unspecified (<50%)
    • Accuracy (OxiMax): ±2% (70% to 99% range), unspecified (<70%)
  • Heart (Pulse) Rate:
    • Range: 20 to 300 bpm
    • Accuracy: Greater than ±1 bpm or ±1% of reading
  • Alarms:
    • Indication: Audible; Visual
    • Volume: 10 levels or Off
    • Silence: Yes; 2 minutes or permanent
  • Trend Memory:
    • Memory: Last 24 hours
    • Parameters: SpO2, pulse rate, NIBP, temperature
  • Displays:
    • Type: LED
    • Parameters: NIBP, SpO2, temperature, pulse rate, pulse bar
  • Printers:
    • Type: Thermal-array
  • Mechanical:
    • Weight: Base unit with battery: 6.95 lbs (3.15 kg)
    • Size: Base unit: 8.7” (H) x 7.1” (W) x 6.5” (D); 22 cm (H) x 18 cm (W) x 16.5 cm (D)
  • Power Requirements:
    • Voltage: 100 to 240 VAC, 50 to 60 Hz
    • Battery: Sealed lead acid; Life: 8 hours
  • Environmental:
    • Operating Temperature: 32º to 113º F; 0º to 45º C
    • Storage Temperature: 23º to 122º F; -5º to 50º C
    • Operating Humidity: 15% to 90%, non-condensing
  • Classification:
    • Type of Protection: Class I equipment
    • Degree of Protection: Type CF defibrillator-proof equipment
    • Protection against Ingress: IPX1 rating, Drip-Proof Equipment