Description
Features:
- The Dräger Infinity Delta is a patient monitor designed to accompany the patient from bedside to transport seamlessly.
- Features a 10.4-inch TFT color LCD display for clear visualization of vital signs.
- Offers various monitoring parameters including 3, 5, 6, and 12 lead ECG, respiration, ST segment analysis, etCO2, BiSx, EEG, NIBP, IBP, multiple temperatures, and full arrhythmia.
- Provides 24 hours of trending data storage for comprehensive patient monitoring.
- Can operate as a standalone monitor or be connected to the Infinity Network for expanded capabilities.
- Supports both wired and wireless configurations for flexible use.
- Customizable to meet hospital or individual patient needs.
- Utilizes pick-and-go technology to ensure continuous monitoring during patient transport.
- Suitable for neonatal, pediatric, and adult patients.
Dräger Infinity Delta Specifications:
- Dimensions:
- Height: 10.0 inches (25.3 cm)
- Width: 14.4 inches (36.5 cm)
- Depth: 7.5 inches (19 cm)
- Weight: 12.7 lbs (5.8 kg) (Without external battery)
- Display:
- Type: Thin Film Transistor-Liquid Crystal Display Active Matrix (TFT-LCD)
- Size (Diagonal): 10.4 inches (26.4 cm)
- Resolution: 640 x 480 Pixels
- Channels: 5 Standard, 6, and 8 Optional
- Viewing Area: 8.3” x 6.2” (21.1 x 15.8 cm)
- Battery:
- Type: Rechargeable Lithium-ion
- Capacity: 180 minutes
- Charging Time: 6.5 hours
- ECG:
- Displays up to 12 leads
- Heart Rate Range: 15 to 300 bpm
- Accuracy: ±2 bpm or ±1% (whichever is greater)
- Respiration:
- Measuring Method: Impedance pneumography
- Measuring Range: 0 to 155 breaths per min
- Accuracy: ±1 breath/min or 2% of rate (whichever is greater)
- SpO2:
- Masimo SET, Nellcor OxiMax, Dräger OxiSure
- Measuring Range: 1 to 100%
- Pulse Measuring Range: 30 to 250 bpm
- NBP (Noninvasive Blood Pressure):
- Displayed Parameters: Systolic, Mean, and Diastolic pressures
- Measuring Method: Oscillometric utilizing step deflation
- IBP (Invasive Blood Pressure):
- Displays up to 8 pressures
- Measuring Method: Resistive strain gauge transducer
- Measuring Range: -50 to 400 mmHg (after zeroing)
- Electrical:
- Input Voltage: 11 to 15 V DC
- Power Consumption: ≤70 Watts (fully loaded)
- Patient Leakage Current: ≤10 mA
- Operating Specifications:
- Temperature: 50°F to 104°F (10°C to 40°C)
- Humidity: 20% to 90%, non-condensing
- Atmospheric Pressure: 525 to 795 mmHg (70 to 106 kPa)
- Storage Specifications:
- Temperature: -4°F to 104°F (-20°C to 40°C)
- Humidity: 10% to 95%, non-condensing (With packaging)
- Atmospheric Pressure: 375 to 795 mmHg (50 to 106 kPa)