Dräger Infinity Delta

Single Product Request Form
Category

Description

Features:

  • The Dräger Infinity Delta is a patient monitor designed to accompany the patient from bedside to transport seamlessly.
  • Features a 10.4-inch TFT color LCD display for clear visualization of vital signs.
  • Offers various monitoring parameters including 3, 5, 6, and 12 lead ECG, respiration, ST segment analysis, etCO2, BiSx, EEG, NIBP, IBP, multiple temperatures, and full arrhythmia.
  • Provides 24 hours of trending data storage for comprehensive patient monitoring.
  • Can operate as a standalone monitor or be connected to the Infinity Network for expanded capabilities.
  • Supports both wired and wireless configurations for flexible use.
  • Customizable to meet hospital or individual patient needs.
  • Utilizes pick-and-go technology to ensure continuous monitoring during patient transport.
  • Suitable for neonatal, pediatric, and adult patients.

Dräger Infinity Delta Specifications:

  • Dimensions:
    • Height: 10.0 inches (25.3 cm)
    • Width: 14.4 inches (36.5 cm)
    • Depth: 7.5 inches (19 cm)
    • Weight: 12.7 lbs (5.8 kg) (Without external battery)
  • Display:
    • Type: Thin Film Transistor-Liquid Crystal Display Active Matrix (TFT-LCD)
    • Size (Diagonal): 10.4 inches (26.4 cm)
    • Resolution: 640 x 480 Pixels
    • Channels: 5 Standard, 6, and 8 Optional
    • Viewing Area: 8.3” x 6.2” (21.1 x 15.8 cm)
  • Battery:
    • Type: Rechargeable Lithium-ion
    • Capacity: 180 minutes
    • Charging Time: 6.5 hours
  • ECG:
    • Displays up to 12 leads
    • Heart Rate Range: 15 to 300 bpm
    • Accuracy: ±2 bpm or ±1% (whichever is greater)
  • Respiration:
    • Measuring Method: Impedance pneumography
    • Measuring Range: 0 to 155 breaths per min
    • Accuracy: ±1 breath/min or 2% of rate (whichever is greater)
  • SpO2:
    • Masimo SET, Nellcor OxiMax, Dräger OxiSure
    • Measuring Range: 1 to 100%
    • Pulse Measuring Range: 30 to 250 bpm
  • NBP (Noninvasive Blood Pressure):
    • Displayed Parameters: Systolic, Mean, and Diastolic pressures
    • Measuring Method: Oscillometric utilizing step deflation
  • IBP (Invasive Blood Pressure):
    • Displays up to 8 pressures
    • Measuring Method: Resistive strain gauge transducer
    • Measuring Range: -50 to 400 mmHg (after zeroing)
  • Electrical:
    • Input Voltage: 11 to 15 V DC
    • Power Consumption: ≤70 Watts (fully loaded)
    • Patient Leakage Current: ≤10 mA
  • Operating Specifications:
    • Temperature: 50°F to 104°F (10°C to 40°C)
    • Humidity: 20% to 90%, non-condensing
    • Atmospheric Pressure: 525 to 795 mmHg (70 to 106 kPa)
  • Storage Specifications:
    • Temperature: -4°F to 104°F (-20°C to 40°C)
    • Humidity: 10% to 95%, non-condensing (With packaging)
    • Atmospheric Pressure: 375 to 795 mmHg (50 to 106 kPa)