Dräger Infinity Delta XL

Single Product Request Form
Category

Description

Features:

  • The Dräger Infinity Delta XL is capable of monitoring adult, pediatric, and neonatal patients with varying acuity levels.
  • Provides continuous monitoring and data collection, suitable for bedside use, during transport, or anywhere in between.
  • Seamless wired-to-wireless networking through connectivity options like the Infinity Docking Station, DirectNet, or a wireless adaptor.
  • Features a 12.2-inch TFT-LCD display for clear visualization of vital signs.
  • Offers 6 standard channels and 8 optional channels for comprehensive monitoring.
  • Provides 24 hours of trended parameter data storage for analysis and review.
  • Utilizes a rechargeable lithium-ion battery for portable operation.

Dräger Infinity Delta XL Specifications:

  • Dimensions:
    • Height: 10.7 inches (27.2 cm)
    • Width: 15.1 inches (38.4 cm)
    • Depth: 7.5 inches (19 cm)
    • Weight: 13.6 lbs (6.2 kg) (Without external battery)
  • Display:
    • Type: Thin Film Transistor-Liquid Crystal Display Active Matrix (TFT-LCD)
    • Size (Diagonal): 12.2 inches (31 cm)
    • Resolution: 800 x 600
    • Channels: 6 Standard, 8 Optional
    • Viewing Area: 9.7” x 7.3” (24.6 x 18.5 cm)
  • Battery:
    • Type: Rechargeable Lithium-ion
    • Capacity: 180 minutes
    • Charging Time: 6.5 hours
  • ECG:
    • Displays up to 12 leads
    • Heart Rate Range: 15 to 300 bpm
    • Accuracy: ±2 bpm or ±1% (whichever is greater)
  • Respiration:
    • Measuring Method: Impedance pneumography
    • Measuring Range: 0 to 155 breaths per min
    • Accuracy: ±1 breath/min or 2% of rate (whichever is greater)
  • SpO2:
    • Masimo SET, Nellcor OxiMax, Dräger OxiSure
    • Measuring Range: 1 to 100%
    • Pulse Measuring Range: 30 to 250 bpm
  • NBP (Noninvasive Blood Pressure):
    • Displayed Parameters: Systolic, Mean, and Diastolic pressures
    • Measuring Method: Oscillometric utilizing step deflation
  • IBP (Invasive Blood Pressure):
    • Displays up to 8 pressures
    • Measuring Method: Resistive strain gauge transducer
    • Measuring Range: -50 to 400 mmHg (after zeroing)
  • Electrical:
    • Input Voltage: 11 to 15 V DC
    • Power Consumption: ≤70 Watts (fully loaded)
    • Patient Leakage Current: ≤10 mA
  • Operating Specifications:
    • Temperature: 50°F to 104°F (10°C to 40°C)
    • Humidity: 20% to 90%, non-condensing
    • Atmospheric Pressure: 525 to 795 mmHg (70 to 106 kPa)
  • Storage Specifications:
    • Temperature: -4°F to 104°F (-20°C to 40°C)
    • Humidity: 10% to 95%, non-condensing (With packaging)
    • Atmospheric Pressure: 375 to 795 mmHg (50 to 106 kPa)