Mindray BeneVision N12

Single Product Request Form
Category

Description

Features:

  1. Modular System: The Mindray BeneVision N12 patient monitor offers a wide variety of monitoring parameters adaptable to different hospital departments. It’s a modular system with integrated module compartments, providing flexibility in patient monitoring.
  2. High-Definition Touchscreen Display: Features a 12-inch high-definition capacitive touchscreen display with touch functions, offering ease of use and intuitive operation.
  3. Extensive Data Storage: Capable of storing trend data, alarms, events, and up to 48 hours of full disclosure, ensuring comprehensive patient recordkeeping.
  4. Compatibility: Compatible with Mindray eGateway for HL7 communication to EMR (Electronic Medical Records), facilitating seamless data integration into hospital systems.
  5. Standard Parameters: Includes standard monitoring parameters such as 3, 5, and 6-lead ECG, Masimo RD SET SpO2, invasive blood pressure (IBP), non-invasive blood pressure (NIBP), respiration, temperature, and arrhythmia analysis with QT/QTc interval monitoring and atrial fibrillation (Afib) detection.
  6. Integrated Recorder: Equipped with a thermal dot array recorder for waveform recording, offering horizontal and vertical resolution, and supporting various paper speeds.
  7. Battery Run Time: Offers over 4 hours of run time when powered by a fully-charged battery, ensuring continuous monitoring even during power outages or transport.

Mindray BeneVision N12 Specifications:

  • Dimensions:
    • Height: 11.4 in (29 cm)
    • Width: 12.3 in (31.3 cm)
    • Depth: 6.3 in (16.1 cm)
    • Weight: 90 lbs (4.1 kg) standard parameters, excluding modules, recorder, battery, and accessories
  • Battery:
    • Type: Rechargeable Lithium-ion
    • Number of Batteries: 1
    • Capacity: 4500 mAh, 11.1 VDC
    • Run Time: Over 4 hours
    • Recharge Time: 4.5 hours to 90% when the monitor is off
  • Display:
    • Type: Medical-grade color TFT LCD
    • Screen Size: 12.1” (Diagonal)
    • Resolution: 1280 x 800 pixels
  • Recorder:
    • Method: Thermal dot array
    • Horizontal Resolution: 16 dots/mm (25 mm/s paper speed)
    • Vertical Resolution: 8 dots/mm
    • Paper Width: 50 mm
    • Paper Length: 20 m
    • Paper Speed: 25 mm/s, 50 mm/s
  • Data Storage:
    • Trends: Minimum of 120 hours of trend data
    • Events: 1000 events
    • NIBP Measurements: 1000 sets
    • Resting 12-lead ECG Interpretations: 20 sets
    • Full-disclosure Waveforms: Up to 48 hours
  • Electrical:
    • Type of Protection: Class I
    • Degree of Protection: MPM/IBP/C.O./NMT/EEG module: CF ScvO2/CO2/AG/rSO2 module: BF
    • Protection Against Ingress of Fluids: IPX1
  • Environmental:
    • Operating Temperature: 0°C to 40°C
    • Storage Temperature: -20°C to 60°C
    • Operating Humidity: 15 to 95% (non-condensing)
    • Storage Humidity: 10 to 95% (non-condensing)
    • Operating Atmospheric Pressure: 427.5 to 805.5 mmHg