Philips Avalon FM30 M2703a Features:
- Fetal and maternal monitor offering cross channel verification to separate maternal pulse rate and blood pressure from fetal heart rate.
- Color touchscreen interface displaying ultrasound, fetal movement, direct fetal heart rate, TOCO, and intrauterine pressure, as well as maternal pulse rate, ECG, SpO2, and blood pressure.
- Cordless transducer system allowing freedom of movement for the mother during continuous monitoring.
- Intuitive color touchscreen with large numerics and graphics for easy interpretation.
- Backup memory for seamless monitoring.
- LAN interface for compatibility with hospital IT networks and access to additional system capabilities.
- Smart transducers with auto-recognition simplify operation.
- Transducer plug and play with automatic screen layout to focus on the patient.
- Data buffer with multi-patient handling for random printout.
- Cross-channel verification of maternal and fetal heart rates.
Philips Avalon FM30 M2703a Specifications:
- Dimensions (M2702A/M2703A):
- Height: 5.2 in (133 mm)
- Width: 11.3 in (286 mm)
- Depth: 13.2 in in (335 mm)
- Weight: 11.2 lbs (5.1 kg)
- Dimensions (M2704A/M2705A):
- Height: 6.8 in (172 mm)
- Width: 16.5 in (420 mm)
- Depth: 14.6 in (370 mm)
- Weight: 19.8 lbs (<9.0 kg)
- Display:
- Monitor Screen: 6.5 in / 16.51 cm
- Touchscreen Operation: Optional
- Battery:
- Operating Time: up to 4 hours
- Environmental Conditions (Monitor Operating):
- Temperature Range: 0°C to 45°C (32°F to 113°F)
- Humidity Range: <95% relative humidity @ 40°C/104°F
- Altitude Range: -500 to 3000 m / -1640 to 9840 ft.
- Environmental Conditions (Monitor Storage):
- Temperature Range: -20°C to 60°C (-4°F to 140°F)
- Humidity Range: <90% relative humidity @ 60°C/140°F
- Altitude Range: -500 to 13100 m / -1640 to 43000 ft.
- Ultrasound (Fetal / Maternal):
- Measurement Method: Ultrasound Pulsed Doppler
- Measurement Range: 50 to 240 bpm
- Display Resolution: 1 bpm
- ECG:
- Measurement Range: 30 to 240 bpm
- Display Resolution: 1 bpm
- Non-invasive Blood Pressure:
- Measurement Ranges: Systolic 30 to 270 mmHg, Diastolic 10 to 245 mmHg, Mean 20 to 255 mmHg
- Accuracy: Max. Std. Deviation: 8 mmHg, Max. Mean Error: ±5 mmHg
- Pulse Rate Range Accuracy:
- 40 to 300 bpm: 40 to 100 bpm: ±5 bpm, 101 to 200 bpm: ±5% of reading, 201 to 300 bpm: ±10% of reading
- Transducers and Measurements: Includes ultrasound fetal heart rate monitoring, fetal movement profile detection, external uterine activity monitoring, Smart Pulse technology for cross-channel verification, NST timer for antepartum applications, and optional maternal noninvasive blood pressure monitoring.
- Monitor: Features high-resolution color TFT touchscreen display, intuitive user functionality via touchscreen, automatic screen layouts, and optional battery operation.
- General Information About Fetal Monitors: Provides an overview of fetal monitoring terminology, monitoring modes (antepartum and intrapartum), and parameters to be considered.