Philips M1012A Cardiac Output Module

Single Product Request Form
Category

Description

Features:

  1. Cardiac Output Measurement: The M1012A Cardiac Output Module provides measurements of Cardiac Output (CO) and Continuous Cardiac Output (CCO) using two measurement methods: the PiCCOTM 1 method and the Right Heart Thermodilution method. These methods are suitable for adult, pediatric, and neonatal patients in critical care environments.
  2. Plug-and-Play Connection: The module can be connected through plug-and-play connection to any monitor in compatible families, including V24 (M1205A), CMS (M1165A/66A/75A and M1175A/76A/77A), and IntelliVue (M8005A, M8007A, M8010A). It sends thermodilution curves, cardiac output numerics, and cardiac index values to the patient monitor display.
  3. COO Measurement Features:
    • COO can be measured using the Transpulmonary Thermodilution or PiCCO Method.
    • Intrathoracic Blood Volume (ITBV) and Extravascular Lung Water (EVLW) values can be derived from the Transpulmonary Thermodilution CO measurement (not in the USA).
    • COO alarms can be generated from Pulse Contour Analysis when the arterial catheter used for Transpulmonary Thermodilution is connected to the module.
    • Continuous Systemic Vascular Resistance values can be derived from COO.
  4. Cardiac Output Features:
    • Absolute and indexed hemodynamic values are displayed.
    • Alarm generation from blood temperature measurement.
    • Patient isolation by internal optical coupling.
    • Hard keys on the module for direct access to commonly performed functions.
    • Light indicators identify the module in use during monitoring tasks.
    • Color-coded patient cable connectors for quick and easy identification.
    • Compact size due to surface mount technology.
  5. Included Specifications:
    • Up to six cardiac output curves and values can be simultaneously displayed.
    • Seven curve alerts.
    • Cardiac output curves are easy to select or reject.
    • Injectate temperature and computation constant.
    • Average of selected curves made with further selectors or rejectors.

Patient Monitor Cardiac Output Module Specifications:

  • Dimensions:
    • Height: 3.9 in (99.6 mm)
    • Width: 1.4 in (36 mm)
    • Depth: 3.8 in (97.5 mm)
    • Weight: 225 g (7.9 oz)
  • Temperature Range:
    • Operating: 0 to 55ºC (32 to 131ºF)
    • Storage: -40 to 70ºC (-40 to 158ºF)
  • Altitude Range:
    • Operating: Up to 4,600 m (15,000 ft)
    • Storage: Up to 15,300 m (50,000 ft)
  • Compatibility:
    • If used in a monitor without PiCCO functionality, only the right heart method can be used (e.g., CMS monitor released earlier than C.0, or V24/V26 monitor).