Features:

  • Monitors pulse rate, temperature, pulse oximetry (SpO2), and calculates Mean Arterial Pressure (MAP).
  • Customizable settings for each patient’s specific needs.
  • Fast and reliable results, allowing vital signs to be taken in half the time of most spot-checking devices.
  • Non-invasive Blood Pressure Monitor with SureBP technology measures blood pressure in about 15 seconds as the cuff inflates.
  • Options for SureTemp Plus or Braun ThermoScan PRO 4000 Ear Thermometer.
  • Choice of Masimo or Nellcor pulse oximetry.
  • Connectivity to select Health o meter® or Tanita digital scales.
  • Ability to manually enter weight, height, respiration rate, and pain level, and calculate BMI.
  • 50-reading memory for previous data retrieval, review, print, or download.
  • Error messages provide descriptions and solutions.
  • Connects to leading EMRs for automatic vitals capture and documentation.

Specifications:

  • Mechanical Dimensions:
    • Height: 10.63in (27 cm)
    • Length (with PRO 4000): 7.9in (20.32 cm)
    • Length (with SureTemp Plus): 7.5 in (19 cm)
    • Depth: 5.25in (13.34 cm)
    • Weight: 7.5 lbs (3.4 kg)
  • Electrical:
    • AC power supply: 8V DC at 0.75 A
    • Rechargeable sealed lead acid internal battery
    • Battery recharge time: 90% to 100% after 6 hours; 1 additional hour for PRO 4000, 4 additional hours for external printer
    • Simultaneously operates device and charges battery when AC power adapter is plugged in
  • Environmental:
    • Operating Temperature (Device): 50°F to 104°F (10° C to 40° C)
    • Operating Relative Humidity: 15% to 95% (non-condensing)
    • Operating Altitude: -170 m to +4,877 m
    • Storage Temperature: Device with SureTemp Plus: -13°F to 131°F (-25° C to 55° C); Device with PRO 4000: -4°F to 122°F (-20° C to 50° C)
    • Storage Humidity: 15% to 95% (non-condensing)
    • EMC Standard: IEC/EN 60601-1-2:2001
  • Non-invasive Blood Pressure (NIBP):
    • Cuff Pressure Range: 0 to 300 mmHg (0 to 40.0 kPa)
    • Systolic Range: 60 to 250 mmHg (8.0 to 33.3 kPa)
    • Diastolic Range: 30 to 160 mmHg (4.0 to 21.3 kPa)
    • Mean Arterial Pressure Range: 40 to 190 mmHg (5.3 to 25.3 kPa)
    • Blood Pressure Accuracy: Meets or exceeds AAMI SP10:2002
    • Overpressure Cutoff: 315 mmHg ±15 mmHg (42.0 kPa ±1.9 kPa)
    • Blood Pressure Determination Time: Typical 15 seconds
    • Pulse Rate Range: 35 to 199 bpm
    • Pulse Rate Accuracy: ±5.0%