Dräger Infinity M300

Single Product Request Form
Category

Description

Features:

  • The Dräger Infinity M300 is a hand-held pulse oximeter and patient monitor capable of monitoring ECG, heart rate, and SpO2.
  • Utilizes wireless network technology and a monitoring station for continuous patient monitoring, even when out of range.
  • Suitable for patients from pediatrics to adults.
  • Features a built-in color screen displaying waveforms and vital sign values for local surveillance.
  • Equipped with visible and audible alarms to immediately alert healthcare providers to changes in the patient’s condition.
  • Integrated Arrhythmia Classification Expert (ACE®) and pacer detection algorithms.
  • Built-in SpO2 functionality, eliminating the need for an additional pulse oximetry device or module.
  • Wi-Fi CERTIFIED technology ensures reliable data transfer on standard wireless networks.
  • Supports WPA2 encryption using 802.11 b/g for enhanced security.

Dräger Infinity M300 Specifications:

  • Dimensions:
    • Height: 5.6 inches (14.2 cm)
    • Width: 3 inches (7.6 cm)
    • Depth: 1.2 inches (3.1 cm)
    • Weight: 10.5 oz (295 g)
  • Display:
    • Size / Viewing Area: 2.2 inches (5.5 cm) diagonal
    • Resolution: 220 x 176 pixels
  • Communications:
    • Network: IEEE 802.11b/g/n (2.4 GHz); 802.11a/n (5 GHz)
    • Wireless Encryption: WPA2 – Personal Mode; WPA2 – Enterprise Mode
    • Radio Power Output: (2.4 GHz); 25mW maximum (5 GHz)
  • Battery:
    • Power Source: Rechargeable 3.75 V lithium-ion battery
    • Battery Operating Time:
      • ECG only: 17 to 19 hours
      • ECG + Continuous SpO2: 14 to 16 hours
      • Operation time varies according to the use of display, alarm alerts, and wireless environment (roaming)
    • ECG:
      • Adult / Pediatric
      • Various lead configurations including 5-wire, 6-wire, and 12-lead with Infinity TruST
      • Detected Events / Rhythms: Asystole, Ventricular Fibrillation, Ventricular Tachycardia, Bradycardia, Ventricular Run, Accelerated Idioventricular Rhythm, Supraventricular Tachycardia, Ventricular Couplet, Ventricular Bigeminy, Tachycardia, Pause, Artifact, PVC/min
      • Pacemaker Detection
    • ST Segment Analysis:
      • Leads Analyzed: Various configurations including 3-wire, 5-wire, 6-wire, and 12-lead with Infinity TruST
    • Pulse Oximetry (Optional):
      • Parameter Display: Percentage of functional (oxygen-saturated) hemoglobin (%SpO2); pulse rate
      • Measuring Method: Absorption-spectrophotometry